Stereo Microscopes

  • The Leica EZ4 educational stereomicroscope with 4.4:1 zoom for entry level university and college courses such as biology, anatomy and chemistry provides over 20 years of bright LED illumination which saves time and cost of replacement bulbs.
  • For analog microscope inspections the S9 E is an indispensable asset. It provides a cost-effective solution with fast return on investment.
  • The S9 D gives you the flexibility to add a camera to the microscope and turn it into a digital microscope solution. The built in 50:50 split of the beam path allows observation through the eyepieces and digital imaging at the same time.
  • The M50, M60, and M80 allow operators to see a large sample overview, work comfortably under the microscope, and capture images of important details easily.
  • with 5:1-zoom, featuring a step-zoom with five fixed zoom steps, at 6.3x, 10x, 16x, 25x, and 40x– allowing 100% reproducible results, this ensures that the results remain comparable at all times without great effort. The short optics carrier enables high light throughput and provides a large working distance, ideal in animal surgery and similar applications.
  • M60 with 6:1-zoom range, with a continuous zoom from 6.3x – 40x including engageable click stops - making repetitive inspection and measurement at a specific zoom position reliable. This system is optimized for a larger field of view to see more at a glance.
  • M80 with 8:1-zoom range, with a continuous zoom from 7.5x – 60x including engageable click stops – expanding your insights and reliability. Optimized for higher magnification to see smaller details in perfect contrast. The large working distance and brilliant imaging power show the finest details of your specimens without losing the field of view over large specimens
  • With a Leica M-series stereo microscope you can choose from a comprehensive range of accessories to adapt your microscope to your application Our goal: high-quality images that allow measurements and can be accurately repeated with minimal effort. The Leica coded stereo microscopes help you to pave the way to correct results.
  • With a coded zoom and apochromatic optics, the Leica M125 C offers high-end quality for mid-range budgets. Combining optimal resolution and depth of field with the integrated double iris diaphragm.
  • Do you have to perform a wide variety of tasks but don’t want to constantly change the objective or even switch the microscope? Offering a large zoom and magnification range the Leica M165 C allows you manage all different kind of samples.
  • The Leica LED5000 / Leica LED3000 family is also fully integrated into the complete system of stereomicro­scopes and accessories from Leica Microsystems Focusing columns with integrated electronics connect all digital signals and send them to Leica Application Suite
  • The light is arranged in a ring around the objective and shines down onto the sample. Illuminate from defined segments or uniformly, depending on the properties of the sample
  • The Leica LED3000 SLI and Leica LED5000 SLI each feature two bright LED spotlights, which can be individually adjusted to the sample with two goosenecks. The control element is mounted on a separate gooseneck and can be placed in any position.
  • The Leica LED3000 NVI is ideal for viewing recesses and holes, since the light falls almost vertically on the sample. In contrast to coaxial illumination it is also ideally suited for non-reflective and uneven sample Surface. NVI illumination shines almost straight down onto the sample plane. This allows cavities and recesses to be very well illuminated. The Leica NVI is installed between the microscope carrier and the objectives
  • The unique Leica MCI (Multi Contrast Illumination) systems are ideal for applications that previously required goosenecks. The flat angle of the oblique incident light creates particularly high contrast for precise viewing of even the smallest uneven surfaces and defects such as scratches and dust particles.
  • The Leica LED5000 CXI coaxial illuminator is used for quality control of flat, polished, or reflective samples. Scratches, cracks, impurities, and pores are made exceptionally visible. With coaxial illumination, light is coupled directly into a beam path and reflected into another beam path by the flat sample.
  • For transmitted light applications. The Leica LED3000 BLI makes it easy to equip a microscope system with transmitted light. The illuminator can be combined with standard baseplates or even used as a standalone instrument.
  • Diffused illumination gives uniform illumination without shadow and glare effects. The Leica LED3000 DI and LED5000 HDI are ideal for documenting samples that are difficult to illuminate using other methods.
  • TL3000 Ergo from Leica stands for intuitive manual operation. Effortlessly pass through the different contrast options: brightfield, Rottermann contrast, or one-sided darkfield. Fine-tuning of the contrast is easy, and all with just a single knob.
  • With the TL5000 Ergo you can manage and control all base settings via software for maximum control, whatever your project. Manual push buttons on the base allow cycling through the different contrasts
  • The Leica CLS LED light source has been developed for routine and high-end microscopy applications. It is compatible with all fiber-optic light guides of the LED series.
  • The purpose of the Leica motor-focus system is to provide motor-driven coarse and fine focusing by means of a manual control, a footswitch, or through a computer. Five exact focus settings can be stored.
  • Leica Swingarm Stands (boom stands) are ideal to handle large samples. The high modularity allows to customize these stands depending on sample size and weight of the configuration. Focus arms and drives provide multiple mounting options and more safety features.
  • The Leica Flexarm stand can rotate 360° and has a radius of up to one meter, making it highly mobile. This allows for convenient viewing of large samples, which should not or cannot be moved. This is ideal for inspection, assembly, and quality control in electronics manufacturing, in dental laboratories and many other applications.