Histopathology

  • The Apex BOND is an extension of the Apex Adhesive Slides portfolio that is specifically designed and validated for IHC staining on the BOND platform. The eight dots represent the usable areas of the Apex BOND for the different dispense volumes in the BOND processing modules.
  • The Apex clipped corners are clipped at 45° angles to help reduce glass breakage and fragmentation when loaded into slide printers.
  • Apex Patient Control Box Slides have clearly designated areas for positive control and patient tissues.
  • Beveled Edge Slides feature beveled edges and corners that make for easier handling. The 25 mm x 75mm slides are washed and carefully inspected to ensure quality.
  • Blue Ribbon is a universal paraffin containing synthetic polymers that can be used both as an infiltration and embedding medium.
  • These slides are 3”x 1” White Snowcoat slides with two circles, each having a diameter of 1/2”. These circles match up with the Cytology Funnel, which is to be used for preparation of non-gyn cytology specimens.
  • The Classic Series high-profile disposable microtome blade is a unique super blade that rivals the traditional reusable microtome blade for routine sectioning.
  • The Classic Series low-profile disposable microtome blades / triple facet microtome blades are manufactured from high carbon stainless steel.
  • More than 20 years of experience have led us to develop and manufacture a wide variety of dissection and necropsy tables, including the veterinary area. We have a wide range of models (see attached photos).
  • More than 20 years of experience have led us to develop and manufacture a wide variety of dissection and necropsy tables, including the veterinary area. We have a wide range of models (see attached photos).
  • More than 20 years of experience have led us to develop and manufacture a wide variety of dissection and necropsy tables, including the veterinary area. We have a wide range of models (see attached photos).
  • More than 20 years of experience have led us to develop and manufacture a wide variety of dissection and necropsy tables, including the veterinary area. We have a wide range of models (see attached photos).
  • More than 20 years of experience have led us to develop and manufacture a wide variety of dissection and necropsy tables, including the veterinary area. We have a wide range of models (see attached photos).
  • EM-400 Embedding Medium is a blend of purified paraffin with synthetic polymers that enables sectioning with minimal compression.
  • ET-101 Series consists in a basic grossing station with all necessary features to satisfy any safety regulation. Its functions are controlled from the upper control panel.
  • The grossing stations ET-100 SERIES form a family of products characterized by their flexibility of adaptation to space and the versatility of configuration.
  • Formula 'R' is a next generation paraffin that enables thin sectioning with minimal compression and all-around ease of use.
  • The thin-layer preparation for the gynaecological cytology with the FDA certified Rovers® Cervex-Brush® Combi. Important scientific publication for gynaecologists: Sampling with the Rovers® Cervex-Brush® Combi results in the collection of the same amount of squamous cells, but in a two to threefold harvest of endocervical cells. This leads to the detection of a higher viral load of oncogenic HPV and an increase in the number of detected abnormal smears. Publication in Cytopathology 2006/17 p. 374-381 Improved endocervical sampling and HPV viral load detection by Cervex-Brush® Combi C. E. Depuydt*, I.H. Benoy, E. J. Bailleul**, J. Vandepitte*, A. J. Vereecken* and J. J. Bogers*** *Laboratory for Clinical Pathology (Labo RIATOL), Antwerp, Belgium, **Department of Gynecology, Sint-Vincentius Ziekenhuis, Nortsel, Belgium and ***Laboratory of Cell and Tissue Research, Faculty of Medicine, University of Antwerp, Antwerp, Belgium.
  • High-profile 818 disposable blades are made of stainless steel with exceptional durability. Ultrafine yet durable, the 80 mm long x 14 mm high x 0.35 mm thick blades are specifically designed for use with Leica Biosystems microtomes or cryostats classified and labelled as in vitro diagnostic medical devices for histological medical diagnosis, e.g. cancer diagnosis.
  • When your application calls for thicker sections, look to the high-profile disposable blades DB80HS with sharpness, longevity and consistency.
  • The HistoCore Arcadia modular tissue embedding system incorporates two separate components, the Arcadia H heated embedding module and the Arcadia C cold plate. The independent modules offer the flexibility to arrange the embedding workflow in the direction that best suits your laboratory.
  • HistoCore Arcadia C is a cold plate holding more than 60/65 cassettes on its large working surface. Cooling efficiency is important, so the cold plate was designed with an environment adaptive control module to make sure the operating temperature is always stabilized at -6 °C. There is no need to turn down the temperature in summer or worry about too fast cooling in winter. The Arcadia C cold plate can be used as a stand-alone unit for re-cooling blocks prior to sectioning or as part of an embedding center to cool molds after paraffin dispensing.
  • We know how important embedding is for you, so we designed the HistoCore Arcadia H Paraffin Dispenser to meet your needs. The HistoCore Arcadia H allows for simple operation and precise control, resulting in improved quality, a smooth workflow, reliability and speed of your embedding work. Features include wristpads for increased comfort and stability; an improved magnifier for small biopsy embedding; and an LCD touchscreen for increased control and monitoring of the instrument.
  • The new generation of microtomes from Leica Biosystems is built upon our 145+ year heritage of market-leading microtome design. It allows users to select among automated, semi auto-automated, or manual sectioning modes based their personal preferences.
  • The new generation of microtomes from Leica Biosystems is built upon our 145+ year heritage of market-leading microtome design. With new options such as the personalized coarse feed wheel and 2-in-1 blade holder, it ranks among the most ergonomically-friendly microtomes on the market. Quickly and efficiently select the turn direction most comfortable for you with the Personalized Coarse Feed Wheel.
  • When you need the precision and speed of manual sectioning with the efficiency benefits of a semi-automated setup, the HistoCore MULTICUT saves the day. The new generation of microtomes from Leica Biosystems is built upon our 145+ year heritage of market-leading microtome design. Combining the speed of a manual microtome with the precision of motorized specimen feeding, MULTICUT helps you get consistent, reproducible sections. Produce high quality sections for IHC when using MULTICUT with the RM CoolClamp.
  • HistoCore PEARL is a compact instrument with a small footprint to maximize your laboratory space. It also provides the essential features needed for added safety, efficient tissue processing and optimized workflows.
  • Build your future with HistoCore PELORIS 3. Meet today's workflow demands and build your lab's capacity for the future. With a HistoCore PELORIS 3 tissue processor, feel confident with Track and Trace features designed to maximize productivity for efficient and flexible workflow, while maintaining quality.
  • The Compact Slide Printing Solution that helps to reduce errors and maintain efficiency. We know how important patient safety is to your laboratory. With the PERMA S slide printer solution you can print individual slides at any microtome workstation. This provides the confidence that you have the right patient tissue associated with the right case number. On-demand direct printing helps reduce the risk of specimen misidentification and securely links patients to samples. The HistoCore PERMA S slide printer, combined with the validated PERMASLIDE slides, generates the high-quality printed barcodes required in your laboratory.
  • The first and only solution in the market with dual glass coverslip lines enabling the highest throughput: up to 570 dried slides per hour. With an integrated hot air-drying oven, it achieves a drying time of only 5 minutes, providing the fastest turnaround time for your lab.
  • The HistoCore SPECTRA ST is a high throughput routine H&E stainer with the uncompromised flexibility to process H&E and special stains simultaneously by maintaining high throughput. The optimized and validated protocols with specifically designed consumables provide unmatched and consistent staining results for the wide range of intensities pathologists expect.
  • Your time matters. Speed up slide processing while maintaining quality and consistency with the HistoCore SPECTRA Workstation, the only workstation that provides consistent staining from slides 1 to 1,600. It also offers the fastest glass coverslipping drying time on the market at only 5 minutes, processing slides that are instantly dry to the touch.
  • Designed for routine and research histopathology of up to 300 cassettes. Proven technology combined with top quality components. Optional RemoteCare diagnostic provide superior instrument reliability. Simplify user operations with an intuitive user interface, color touch screen and a variety of "smart" features. Improve specimen quality and laboratory economy with the Reagent Management System and quick start for commonly used programs.
  • Focus on what’s critical: Quality, specimen safety, productivity. The ASP6025 supports diagnostic clarity thanks to an optimized reagent management system and validated processing protocols. Built-in safety features and reagent quality control deliver specimen protection and accurate processing results.
  • The New ASP6025 S is designed to improve your lab’s performance with quality-driven technology that optimizes tissue processing performance and supports rapid processing. Designed for increased performance and reliability, the new ASP6025 S processes up to 300 cassettes simultaneously for faster turnaround times.